3 Detailed checklist
Checklist
Article ID: 109745536, V2.0, 05/2022
22
© Siemens AG
2022 All rights reserved
3.12.3 WLAN iPCF
Menu path
You can find this information in IWLAN devices in the following menu:
"iFeatures > iPCF".
Recommendation
Use deterministic "iPCF" if you wish to transmit time-critical data
such as PROFINET over the wireless link.
Use "iPCF" together with IEEE 802.11a (not IEEE 802.11n) for a more stable
connection.
Note
"Standard DCF" cannot guarantee fixed transmission times and is therefore not
deterministic.
Note
"iPCF" is proprietary on SCALANCE devices and cannot be used with access
points or clients from third-party vendors.
3.13 Configuration
3.13.1 Storage information with MSPS devices
The devices save their configuration automatically in parallel:
Immediately after modification, in volatile RAM
With a 60-second delay after the modification, permanently in the flash storage
(and C-PLUG where applicable)
The goal is to minimize write access to the flash while the user is making changes.
After each change in the WBM, the following message will appear in the upper half
of the screen:
"Changes will be saved automatically in <xy> seconds. Press "Write Startup
Config" to save immediately".
Note
The change you made on the SCALANCE device is active immediately and has
been applied.
There is no reason to use "Write Startup Config" after each change. This way of
working runs contrary to the underlying idea, and is not necessary. The same
applies when restarting the SCALANCE device.
Only use "Write Startup Config" to save explicitly in the following cases:
If the device's power supply will be disconnected, otherwise causing the
changes from the last minute to be lost.
In trial mode (see chapter 3.13.4)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE and is the answer not in the manual?

Siemens SCALANCE Specifications

General IconGeneral
Product FamilySCALANCE
FunctionEthernet Switch
Temperature Range-40°C to +70°C (depending on model)
Protection ClassIP20, IP30 (depending on the model)
MountingDIN rail, wall mounting (depending on the model)
Power Supply24 V DC
Number of PortsVaries by model (e.g., 4, 8, 24 ports)
TypeManaged, Unmanaged
SubtypesX, W, M, S
CertificationsCE, ATEX, IECEx (depending on the model)
Network ProtocolsPROFINET, Ethernet