EasyManuals Logo

Siemens SCALANCE User Manual

Siemens SCALANCE
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #25 background imageLoading...
Page #25 background image
3 Detailed checklist
Checklist
Article ID: 109745536, V2.0, 05/2022
25
© Siemens AG
2022 All rights reserved
3.13.4 Scheduled restart and Trial Mode
Menu path
With MSPS devices, you can find this information under "System > Restart".
You can find the "Trial Mode" in MSPS devices under "System > Configuration".
Note
Upon changes to the configuration, there is a risk that the user may lock
himself/herself out of the device as a result of incorrect or unintended changes
(especially with remote access).
The "Scheduled Restart" function restarts the device after a specified time.
This, combined with "Trial Mode", gives you a backstop against misconfigurations.
"Trial Mode" disables cyclic saving of changes to the flash. Changes are only
stored in volatile RAM.
As long as you do not use "Write Startup Config" to save the configuration before
the specified time runs out, the device will restart and discard all changes that were
made after "Trial Mode" was activated.
Recommendation
Use "Trial Mode" if you wish to test a configuration.
Trial Mode does apply new settings but it does not save them to the configuration
file (Startup Configuration).
1. Start "Trial Mode" and enter a time for the restart.
2. Make changes without pressing "Write Startup Config".
3. Check the result.
4. If the result works, then reset the configuration mode to "Automatic Save" and
cancel the scheduled restart. In the event of an error, wait until the specified
time elapses and the device will discard the changes.
5. If the SCALANCE device supports the option for Config backups, you can
select which backup will be activated after the time runs out.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE and is the answer not in the manual?

Siemens SCALANCE Specifications

General IconGeneral
Product FamilySCALANCE
FunctionEthernet Switch
Temperature Range-40°C to +70°C (depending on model)
Protection ClassIP20, IP30 (depending on the model)
MountingDIN rail, wall mounting (depending on the model)
Power Supply24 V DC
Number of PortsVaries by model (e.g., 4, 8, 24 ports)
TypeManaged, Unmanaged
SubtypesX, W, M, S
CertificationsCE, ATEX, IECEx (depending on the model)
Network ProtocolsPROFINET, Ethernet

Related product manuals