Installing the Device
2.3.2Mounting the Device on a DIN Rail
Note
The chassis features multiple mounting holes, allowing the rack mount adapters
to be installed up to 25 mm (1 in) from the face of the device.
1
Rear
2
Front
3
Rack Mount Adapter
Figure2.1 Rack Mount Adapters
2. If required, install adapters on the opposite side of the device to protect from
vibrations.
3. Insert the device into the rack.
4. Secure the adapters to the rack using the supplied hardware.
2.3.2 Mounting the Device on a DIN Rail
For DIN rail installations, the RUGGEDCOM RSG2100 can be equipped with panel/DIN
rail adapters pre-installed on each side of the chassis. The adapters allow the device
to be slid onto a standard 35 mm (1.4 in) DIN rail.
NOTICE
DIN rail mounting is not recommended for constant vibration environments.
To mount the device to a DIN rail, do the following:
1. Align the adapters with the DIN rails and slide the device into place.
RUGGEDCOM RSG2100
Installation Manual, 11/2022, C79000-G8976-1040-20
11