Technical Specifications
5
This section details the specifications and operating conditions of the device.
5.1 Power Supply Specifications
The RUGGEDCOM RSG2100 can be equipped with the following power supplies:
NOTICE
Electrical hazard – risk of power supply failure or damage to the device
Make sure power input to the device is within the specified input range. If power
input is too high, damage to the power supply may occur. If power input is too low,
damage to the device may occur.
Input RangePower
Supply Type
Minimum Maximum
Internal Fuse
Rating
ab
Maximum Power
Consumption
c
24 VDC 10 VDC 36 VDC 6.3 A(F)
48 VDC 36 VDC 72 VDC 3.15 A(T)
HI (125/250 VDC)
d
88 VDC 300 VDC 3.15 A(T)
HI (110/230 VAC)
d
85 VAC 264 VAC 3.15 A(T)
28 W
a
(F) denotes fast-acting fuse
b
(T) denotes time-delay fuse.
c
Power consumption varies based on configuration. 10/100Base-TX ports consume roughly 1 W less than fiber optic ports.
d
The HI power supply is the same power supply for both AC and DC.
5.2 Failsafe Relay Specifications
Maximum Switching
Voltage
250 VAC, 125 VDC
Rated Switching
Current
2 A @ 250 VAC, 0.15 A @ 125 VDC, 2 A @ 30 VDC
Maximum Switching
Capacity
150 W, 500 VA
RUGGEDCOM RSG2100
Installation Manual, 11/2022, C79000-G8976-1040-20
31