EasyManua.ls Logo

Siemens SIMATIC NET RUGGEDCOM RSG2100 - Copper Ethernet Ports

Siemens SIMATIC NET RUGGEDCOM RSG2100
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Communication Ports
4.1Copper Ethernet Ports
1
Port LED
Figure4.2 Port LEDs
LED State Description
Yellow (Solid) Link established
Yellow (Blinking) Link activity
Off No link detected
4.1 Copper Ethernet Ports
The RUGGEDCOM RSG2100 supports several 10/100/1000Base-TX Ethernet ports
that allow connection to standard Category 5 (CAT-5) unshielded twisted-pair
(UTP) cables with either RJ45 or Micro-D male connectors. The RJ45 and Micro-D
connectors are directly connected to the chassis ground on the device and can accept
CAT-5 shielded twisted-pair (STP) cables.
WARNING
Electric shock hazard – risk of serious personal injury and/or equipment
interference
If shielded cables are used, make sure the shielded cables do not form a ground loop
via the shield wire and the RJ45 receptacles at either end. Ground loops can cause
excessive noise and interference, but more importantly, create a potential shock
hazard that can result in serious injury.
Pin-Out
The following are the pin-out descriptions for the RJ45 and Micro-D connectors:
18
Figure4.3 RJ45 Ethernet Port Pin Configuration
NamePin
10/100Base-TX 1000Base-TX
Description
1 RX+ BI_DA+ Receive Data+ or Bi-
Directional Pair A+
2 RX- BI_DA- Receive Data- or Bi-
Directional Pair A-
3 TX+ BI_DB+ Transmit Data+ or Bi-
Directional Pair B+
4 Reserved (Do Not Connect) BI_DC+ Transmit Data+ or Bi-
Directional Pair C+
24
RUGGEDCOM RSG2100
Installation Manual, 11/2022, C79000-G8976-1040-20

Related product manuals