Installing the Device
2.5.1Connecting AC or DC Power
Figure2.8 Assembling the Power Terminal Blocks
Note
Torque all terminal connections to 0.6 N·m (5 lbf-in).
3. Connect the power cable to the device as follows:
HI AC/DC Power Supply
1. Connect the Line wire (AC) or
Positive wire (DC) to the positive/
live (+/L) terminal on the terminal
block.
2. Connect the Neutral wire (AC) or
Negative wire (DC) to the negative/
neutral (-/N) terminal on the
terminal block.
3. Connect the ground wire to the
chassis/ground terminal on the
terminal block.
LO DC Power supply
1. Connect the Positive wire to
the positive (+) terminal on the
terminal block.
2. Connect the Negative wire to
the negative (-) terminal on the
terminal block.
3. Connect the ground wire to the
chassis/ground terminal on the
terminal block.
1
3
2
1
Positive/Live (+/L) Terminal
2
Neutral (-/N) Terminal
3
Chassis/Ground Terminal
Figure2.9 HI AC/DC Terminal Block
Wiring
1
3
2
1
Positive (+) Terminal
2
Negative (-) Terminal
3
Chassis/Ground Terminal
Figure2.10 LO DC Terminal Block Wiring
RUGGEDCOM RST916C
Installation Manual, 04/2023, C79000-G8976-1490-07