Technical Specifications
5.5Operating Environment
e
RMS 1 minute.
5.5 Operating Environment
The RUGGEDCOM RST916C is rated to operate under the following environmental
conditions.
Ambient Operating
Temperature (Non-Hazardous
Environments)
a
-40 to 85 °C (-40 to 185 °F)
Ambient Operating
Temperature (Hazardous
Environments)
a
-40 to 80 °C (-40 to 176 °F)
Ambient Storage Temperature -40 to 85 °C (-40 to 185 °F)
Ambient Relative Humidity
b
5% to 95%
Maximum Altitude 2000 m (6562 ft)
a
Measured from a 30 cm (12 in) radius surrounding the center of the enclosure.
b
Non-condensing.
5.6 Mechanical Specifications
Weight 3.75 kg (8.3 lbs)
Ingress Protection IP40 for LO power supply, IP30 for HI power supply
Enclosure Die Cast Aluminum
5.7 Dimension Drawings
Note
All dimensions are in millimeters, unless otherwise stated.
RUGGEDCOM RST916C
Installation Manual, 04/2023, C79000-G8976-1490-07
31

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET RUGGEDCOM RST916C and is the answer not in the manual?

Siemens SIMATIC NET RUGGEDCOM RST916C Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET RUGGEDCOM RST916C
CategorySwitch
LanguageEnglish

Related product manuals