Configuring with Web Based Management
5.5 "System" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
Configuration Manual, 03/2015, C79000-G8976-C267-08
177
The page contains the following boxes:
●
Enter the name of the group. The maximum length is 32 characters.
●
Select the security level (authentication, encryption) valid for
the selected group. In the security levels, the following options:
– No Auth/no Priv
No authentication enabled, no encryption enabled.
– Auth/no Priv
Authentication enabled / no encryption enabled.
– Auth/Priv
Authentication enabled / encryption enabled.
The table has the following columns:
●
Select the row you want to delete.
●
Shows the defined group names.
●
Shows the configured security level.
●
Enable or disable read access for the required group.
●
Enable or disable wite access for the required group.
Note
For write access to work, you also need to enable read access.
●
Shows whether or not the group is assigned to an SNMPv3 user. If the group is not
assigned to an SNMPv3 user, no automatic saving is triggered and the configured group
disappears again after restarting the device.
– Yes
The group is assigned to an SNMPV3 user.
– No
The group is not assigned to an SNMPV3 user.