Configuring with Web Based Management
5.8 "Layer 3" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
266 Configuration Manual, 03/2015, C79000-G8976-C267-08
5.8
"Layer 3" menu
5.8.1
NAT
5.8.1.1
Basic
Note
This tab is only available in the client mode.
On this page, you specify the basic settings for NAT.
Description
The page contains the following boxes:
Drop-down list "Interface"
From the drop-down list, select the required Ethernet interface.
Check box "Enable NAT"
Enable or disable NAT for the Ethernet interface. Can only be enabled if "Own" is set on
the client for "MAC Mode".
Input box "TCP Idle Timeout [s]"
Enter the required time in seconds. If no data exchange takes place, the TCP connection
is deleted from the translation table when this time has elapsed.
The range of values is 1 to 4294967295.
Default setting: 86400 seconds
Input box "UDP Idle Timeout [s]"
Enter the required time in seconds. If no data exchange takes place, the UDP connection
is deleted from the translation table when this time has elapsed.
The range of values is 1 to 4294967295.
Default setting: 300 seconds

Table of Contents

Other manuals for Siemens SIMATIC NET SCALANCE W700 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE W700 Series and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE W700 Series Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE W700 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals