Technical specifications
12.1 Technical specifications of the PN/J1939 LINK
SIMATIC PN/J1939 LINK
64 Operating Instructions, 12/2018, A5E45307564-AA
Article number
6BK1623-0AA00-0AA0
Interfaces
Interfaces/bus type
2x Ethernet (RJ45), 1x Sub-D (9-pin)
Supports protocol for PROFINET IO
automatic detection of transmission rate
No
Transmission rate, max.
100 Mbit/s
Number of RJ45 ports
2
Number of FC (FastConnect) connections
2
PROFINET functions
Assignment of the IP address, supported
Yes
Assignment of the device name, supported
Yes
CAN
CAN operating modes
J1939 according to the standard "SAE J1939"
Transmission rate, min.
100 kbit/s
Transmission rate, max.
500 kbit/s
Number of slaves, max.
30
J1939
Addressable ECUs, max.
30
Logical nodes, max.
253
PDU 1
Yes
PDU 2
Yes
DM data
Yes
BAM
Yes
CMDT
Yes
1. Interface
Interface type
J1939 according to the standard "SAE J1939"
Physics
9-pin sub D socket
Isolated
Yes; 500 V AC or 707 V DC
Interface types
Number of ports
1