EasyManuals Logo

Siemens SIMATIC S7-1500T Equipment Manual

Siemens SIMATIC S7-1500T
82 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #17 background imageLoading...
Page #17 background image
Properties
Important properties of the SIMATIC Drive Controller:
Fail-safe technology CPU including drive control with safety functions integrated in the
drive
Extremely compact because the CPU is integrated in the drive system without taking up
any additional space
Central data management with one memory card for CPU and SINAMICS Integrated
Easy handling
Less cabling and installation effort thanks to SINAMICS Integrated
Easy configuring in the hardware configuration of STEP7
Central license handling in the TIA Portal
Easy and efficient commissioning and optimization of drives using the SINAMICS Startdrive
engineering tool in the TIA Portal
Optimization function for determining the optimal precontrol and gain (Kv factor) for the
closed loop position control of the axis
Optimized for production machinery
Performance classes and memory size optimized for production machinery
Wide range of interfaces, consistent across performance range
Technology I/Os onboard
12 digital inputs and 16 user-configurable digital inputs/outputs
Up to 8 outputs configurable as high-speed outputs for ultra-short output delays and
maximum switching precision, e.g. can be configured for output cam applications.
Up to 16 inputs configurable as measurement sensing inputs for position detection
Additional technology functions such as oversampling and event/period duration
measurement
Areas of application
SIMATIC Drive Controllers are used, for example, in applications in which the SINAMICS S120
drive family is being used because of the need for:
A highly dynamic, flexible multi-axis drive system:
Broad performance range
Comprehensive range of motors (including external drives, etc.)
Comprehensive control modes (servo, vector, U/f)
SINAMICS Technology Extensions
Controlled infeed/regenerative feedback
For prevention of undesired harmonics
For a high level of robustness against line fluctuations
For energy recovery in braking mode

SIMATIC Drive Controllers are also used where there is a need for:
Safety solutions for machine and operator protection
A compact, space-saving design
High performance for motion control and high-speed I/O
Modular machine concepts with fast isochronous mode  

17
Product overview
3.2 Application range
SIMATIC Drive Controller
Equipment Manual, 11/2022, A5E46600370-AC

Other manuals for Siemens SIMATIC S7-1500T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC S7-1500T and is the answer not in the manual?

Siemens SIMATIC S7-1500T Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC S7-1500T
CategoryController
LanguageEnglish

Related product manuals