Operating Modes, parameters and commands
7.4 Measuring modes
FM 350-1 Counter module
Manual, 05/2011, A5E03648639-01
155
Status of the Outputs and Status Bits
The status of the two outputs is indicated by the green LEDs and the corresponding status
bits in the DB.
Table 7- 45 Output DO0
Limit values Enable bit
CTRL_DO0
Status bit
STS_CMP1/
Output DO0
LED DO0
0 0 Out Not exceeded
1 0 Out
0 0 Out Exceeded
1 1 is lit
Table 7- 46 Output DO1
Control bit
SET_DO1
Enable bit
CTRL_DO1
Status bit
STS_CMP2/
Output DO1
LED DO1
0 0 Out 0
1 0 Out
0 0 Out 1
1 1 is lit