110054 No punch tape format or it is faulty OK softkey
DATA IN-OUT / DATA INPUT / START
No reading-in
No punch tape format found in archive, archive does not have a PC format or transmission was started at the
wrong time
Check external data
110055 Too much data found OK softkey
SERVICES / DATA OUTPUT
There is still more data that cannot be accessed
The currently selected workpiece contains more data than can be displayed or processed (max 240 files)
Select low no. of files for output
110056 PC format can be transmitted only with 8 data bits OK softkey
DATA IN-OUT / ... / ... / START
No data read-in or out
For reading in or out data in PC format the device must be parameterized with 8 data bits
Suitably parameterize interface
110057 File not available OK softkey
DATA IN-OUT / ... / ... / START
File not read out
File is not available on MMC at the archiving time
Faulty archive list or time problem
110058 Transfer aborted OK softkey
DATA ON OFF / ... / ... / START
Not all the data was transferred.
Abort occurred while file was being transferred.
Check cable and peer.
110059 Cannot be transmitted in punch tape format OK softkey
Archiving
Data is not archived.
Only MPF, SPF, TOA, RPA, ZOA, UMS, SEA, TEA1, TEA2, TEA4 can be transmitted in LS format.
Select other data or archive in PC format
110060 Stored in the clipboard OK softkey
DATA IN-OUT / DATA INPUT / START
The file was entered in the clipboard
The file could not be entered in the current directory (not possible, no authorization, file opened from PC editor)
Paste from clipboard into the desired archive location
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
1 Alarms
1.5.1 Alarm description