04/96
Siemens AG 2001 All rights reserved 6FC5198–jAB40
1–173
SINUMERIK 840C / SIMODRIVE 611–D (DA)
165041 Only possible in general reset mode OK softkey
Softkey “Configure memory”
Function is not performed
To configure memory, the control must be in the general reset mode.
Activate the general reset mode under “Diagnosis/start-up”
Applies as from SW 4
165042 Configuration not complete OK softkey
Softkey “Configure memory”, check DRAM and SRAM configuration
Function is not performed
Not all data belonging to the configuration are available
First enter all data
Applies as from SW 4
165043 Insufficient memory space OK softkey
Softkey “Configure memory”, check DRAM and SRAM configuration
Function is not performed
The calculated free memory space available is negative
Change the configuration such that the remaining memory is positive
Applies as from SW 4
165044 Controller data have not been calculated OK softkey
Loading of standard drive machine data and also softkey “Calculate controller data”
Invalid data in the drive
–
Repeat action
Applies as from SW 4
165045 No power section selected OK softkey
Softkey “OK” in the drive machine data/selection module screen
Key is ignored
Line with intermediate heading has been selected accidently. These lines serve only for the headings in the selec-
tion list.
Select the correct module and press the key again.
Applies as from SW 4
165046 No input authorization OK softkey
Insert from clipboard, drive selection
Function is not performed
The data block just edited cannot be modified even if password is set (e.g. standard data block)
Select another data block
Applies as from SW 4
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
1 Alarms
1.5.1 Alarm description