04/96
Siemens AG 2001 All rights reserved 6FC5198jAB40
1–177
SINUMERIK 840C / SIMODRIVE 611D (DA)
165065 Result field weakening speed < rated speed OK softkey
SoftkeyCalculate equivalent circuit diagram data (MSD only)
The equivalent circuit diagram data have not been calculated, the field weakening speed (MD 1142 and 2142) can
now be modified manually.
The calculated field weakening speed is smaller than the rated speed (MD 1400 and 2400). This WarnNote is dis-
played if rated voltage plus the voltage drop at the series reactor exceed 400V.
Correct value of field weakening speed manually.
Applies as from SW 5.4
165066 Current controller gain (MD 1120) not calculable OK softkey
SoftkeyCalculate controller data (FDD only)
The controller data have been calculated, the machine data concerned has been given a suitable default value.
The calculated current controller gain is < 0.
If necessary, correct value and repeat function.
Applies as from SW 5.4
165067 Default value (MD x15) cannot be calculated OK softkey
SoftkeyCalculate controller data (MSD only)
The controller data have been calculated, the machine data concerned has been given a suitable default value.
The result calculated was a default value 0.
If necessary, correct value and repeat function.
Applies as from SW 5.4
165068 Magnetizing reactance (MD x14) not allowed OK softkey
SoftkeyCalculate controller data (MSD only)
The controller data have been calculated, the machine data concerned has been given a suitable default value.
The value 0 has been entered for the magnetizing reactance (MD1141 and MD 2141).
If necessary, correct value and repeat function.
Applies as from SW 5.4
165069 Leakage reactance (MD x139/MD x140) not allowed OK softkey
SoftkeyCalculate controller data (MSD only)
The controller data have been calculated, the machine data concerned has been given a suitable default value.
The value 0 has been entered for one of the leakage reactances (MD 1139, 1140, 2139, 2140).
If necessary, correct value and repeat function.
Applies as from SW 5.4
165070 Rated frequency (MD x134) not allowed OK softkey
SoftkeyCalculate controller data (MSD only)
The controller data have been calculated, the machine data concerned has been given a suitable default value.
The value 0 has been entered for the rated frequency (MD 1134 and MD 2134).
If necessary, correct value and repeat function.
Applies as from SW 5.4
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
1 Alarms
1.5.1 Alarm description

Table of Contents

Other manuals for Siemens SIMODRIVE 611-D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMODRIVE 611-D and is the answer not in the manual?

Siemens SIMODRIVE 611-D Specifications

General IconGeneral
BrandSiemens
ModelSIMODRIVE 611-D
CategoryControl Unit
LanguageEnglish

Related product manuals