Converter data sheets and characteristics
4.2 Water cooling
Commissioning instructions for SIMOTICS M-1PH8 Premium Performance
54 Commissioning Manual, 10/2014, 610.40106.40
Additional parameterization
Booksize 45 A
400 V
480 V
Motor type selection
p300
1
1
Line resistance
p352
0.05
0.05
Current controller adaptation, starting point
KP
p391 0 0
Current controller adaptation, starting point
KP adapted
p392 10 10
Current controller adaptation, P gain adapta-
tion
p393 40 40
Current limit
p640
77
77
Maximum rotation speed
p1082
24,000
24,000
Torque limit, upper/motoring
p1520
26.5
26.5
Torque limit, lower/regenerative
p1521
-26.5
-26.5
Power limit, motoring
p1530
25
27.8
Power limit, regenerative
p1531
-25
-27.8
Maximum field-generating current
p1603
0
0
Pulse frequency setpoint
p1800
4
4
Modulator configuration
p1810
"&H800"
"&H800"
Current controller P gain
p1715
4
4
Reference speed reference frequency
p2000
24,000
24,000
Reference current
p2002
77
77
Reference torque
p2003
26.5
26.5
Hysteresis speed n_act > n_max
p2162
480
480

Other manuals for Siemens SIMOTICS M-1PH8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTICS M-1PH8 and is the answer not in the manual?

Siemens SIMOTICS M-1PH8 Specifications

General IconGeneral
BrandSiemens
ModelSIMOTICS M-1PH8
CategoryEngine
LanguageEnglish

Related product manuals