Converter data sheets and characteristics
4.2 Water cooling
Commissioning instructions for SIMOTICS M-1PH8 Premium Performance
70 Commissioning Manual, 10/2014, 610.40106.40
Additional parameterization
Booksize 45 A SLM
400 V
480 V
Motor type selection
p300
1
1
Line resistance
p352
0.041
0.041
Current controller adaptation, starting point
KP
p391 0 0
Current controller adaptation, starting point
KP adapted
p392 12.5 12.5
Current controller adaptation, P gain adapta-
tion
p393 45 45
Current limit
p640
56
75
Maximum rotation speed
p1082
24,000
24,000
Torque limit, upper/motoring
p1520
54
72
Torque limit, lower/regenerative
p1521
-54
-72
Power limit, motoring
p1530
28.3
41.5
Power limit, regenerative
p1531
-28.3
-41.5
Maximum field-generating current
p1603
0
0
Pulse frequency setpoint
p1800
4
4
Modulator configuration
p1810
&H800
&H800
Current controller P gain
p1715
5.8
5.8
Reference speed reference frequency
p2000
24,000
24,000
Reference current
p2002
56
75
Reference torque
p2003
54
72
Hysteresis speed n_act > n_max
p2162
480
480