Connecting
5.4 System integration
1FK7 G2 synchronous motors
76 Operating Instructions, 05/2021, A5E50907562B AA
4. After you have pushed the disassembly protection sleeve completely over the connector
connection, insert the supplied screw through the drill holes in the disassembly protection
sleeve.
Note
Depending on the version, the disassembly protection sleeves
can have two drill holes.
Select the drill hole nearest the connector.
2
Cylinder head screw
for M23 connector: M4 x 35, property class 8.8
for M40 connector: M5 x 60, property class 8.8
5. Tighten the screwed connection until a friction-locking connection results.
Note
To achieve adequate grounding, a metallic contact must be made between the
disassembly protection sleeve and the connector or mating connector.
You have installed the disassembly protection sleeve.
Securing an RJ45 connection
Instead of the angle plug, the DRIVE-CLiQ connection of the encoder can also be an RJ45
connector.
The following procedure describes the securing of an RJ45 connection.
Required parts
Loosening protection for RJ45 connector