Name Description
Resistance when warm (100°C) ca.1380Ω
Characteristic of a Pt1000
















7ሗ&
5˖
System requirements for the Pt1000 temperature sensor
To use the Pt1000 together with the following systems, you will need at least the speci󹪝ed
versions:
SINAMICS S120 Firmware V4.8 and V4.7 HF17
SINUMERIK V4.8 as well as V4.7 SP2 HF1 and V4.5 SP6
SIMOTION V4.5 (SINAMICS Integrated Firmware V4.8)
Description
3.4Design
1FW6 built-in torque motors
Operating Instructions, 09/2022, A5E52220812B AA 57