Preparations for use
4.6 Ensure adequate cooling
1MB..5/6 shaft height 71 ... 355
42 Operating Instructions, 07/2020, A5E41926185A
Incorrect
Correct
Minimum dimension "x" for the distance between neighboring modules and the air intake of the ma-
chine
Table 4- 2 Minimum dimension "x" for the distance between adjacent modules and the air intake of
the machine
Shaft height x
mm
63 ... 71
15
80 ... 100
20
112
25
132
30
160
40
180 ... 200
90
225 ... 250
100
280 ... 315
110
355
140