EasyManua.ls Logo

Siemens SIMOTICS XP - Mounting and Installed the Machine; Preparing the Assembly Area; Lift the Machine to Where It will be Mounted and Position It

Siemens SIMOTICS XP
154 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Assembly
5.4 Alignment and fastening
1MB..5/6 shaft height 71 ... 355
Operating Instructions, 07/2020, A5E41926185A
59
Smooth running
Preconditions for smooth, vibration-free operation:
Stable foundation design free of any shock or vibration.
A precisely aligned coupling.
A well-balanced drive output element (coupling, belt pulleys, fans, ...)
Maintain the maximum permissible vibration values in operation according to ISO 10816-
3.
Avoid inadmissible vibration caused by imbalance, for example (drive output element),
external vibration or any resonance over the complete speed range.
It may be necessary to completely balance the machine with the drive output element or
the system resonance frequency must be shifted.
Foot mounting/flange mounting
Use the specified thread size laid down in EN 50347 when flanging the machine to a
foundation or a machine flange.
Mount the machine at all the foot or flanged holes provided. The choice of fixing
elements depends on the foundation and is the plant operator's responsibility. Comply
with the required property classes for screwed connections and materials for fixing
elements.
Select the correct screw length for IM B14 flanges.
Ensure that the screw heads are in full contact with the flange surface. Use additional
flat washers (ISO 7093), especially for elongated foot mounting holes.
5.4.3 Flatness of the supporting surfaces for conventional motors
Shaft height Flatness
[mm]
≤ 132
0.10
160
0.15
≥ 180
0.20