Safety information
2.8 Electromagnetic compatibility
1MB..5/6 shaft height 71 ... 355
16 Operating Instructions, 07/2020, A5E41926185A
The ESD protective measures required for components that can be destroyed due to
electrostatic discharge are shown in the following drawings:
a = conductive floor sur-
face
f = cabinet ground connection
Risk of explosion due to electrostatic discharge
Electrostatic discharge poses a potential ignition source. Dangerous electrostatic charges can
occur, for example as a result of mechanical friction, flowing air that contains particles - or
persons that are not appropriately grounded, e.g. when carrying out maintenance or cleaning
work.
In an explosive atmosphere, there is a risk of an explosion. This can result in death, serious
injury or material damage.
• Avoid carrying out work specified above on non-metallic parts, e.g. foam rubber for noise
dampeners/attenuators.
• Please comply with ESD protective measures.
2.8 Electromagnetic compatibility
Electromagnetic compatibility
This machine is designed in accordance with IEC/EN 60034, and when used as specified, it
complies with the requirements of European Directive 2014/30/EU regarding Electromagnetic
Compatibility.
2.9 Interference immunity
By selecting suitable signal cables and evaluation units, ensure that the interference
immunity of the machine is not diminished.