Operation
8.1 Safety instructions for operation
1MB..5/6 shaft height 71 ... 355
96 Operating Instructions, 07/2020, A5E41926185A
CAUTION
Risk of injury when touching the fan
There is a risk of injury at machines equipped with a fan cover (e.g. on machines in the
textile industry), as the fan is not completely touch protected.
Do not touch the rotating fan.
Do not put your fingers into the larger air discharge openings.
Prevent manual intervention by using suitable measures, e.g. appropriate housings or a
protective grating.
8.1.2 Switching on with the anti-condensation heating active
Excessively high machine temperature when heating is switched on
If the anti-condensation heating is operated while the machine is running, this can increase
the temperatures inside the machine. Material damage can result.
Make sure that the anti-condensation heating is switched off before the machine is
switched on.
Only operate anti-condensation heating when the machine is switched off.
WARNING
Explosion hazard
If the anti-condensation heating is switched on during operation, the temperature class or
the maximum surface temperature of the machine can be exceeded.
In an explosive atmosphere, there is a risk of an explosion. This can result in death, serious
injury or material damage.
Only switch on the anti-condensation heating after the motor has been switched-off.
Comply with the data stamped on the plate of the anti-condensation heating, if
available.