EasyManuals Logo

Siemens Simotion TM 121C User Manual

Siemens Simotion TM 121C
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #45 background imageLoading...
Page #45 background image
Procedural functions of mechanical presses
© Siemens AG 2003 All Rights Reserved
SIMOTION Safety Unit (AP) - Edition 06.2003
5-45
5.4 Valve monitoring
If, for mechanical safety reasons, the clutch/brake-combination is equipped with
limit switches that display the switching position of the valves, these are read in via
the feedback inputs in the control unit and compared to the activation of the outputs
(watchdog timer).
Note
If an electrical valve monitor is not in use, monitoring must be accomplished by
means of other measures with a comparable degree of safety (hydraulic or
electric).
Parameterization
Figure 5-8 Mechanical operation – Watchdog timer

Table of Contents