EasyManuals Logo

Siemens SIMOTION TM15 User Manual

Siemens SIMOTION TM15
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #15 background imageLoading...
Page #15 background image
When assessing the machine's risk in accordance with the respective local regulations (e.g.
EC Machinery Directive), the machine manufacturer must take into account the following
residual risks emanating from the controller and drive components of a drive system:
1. Unintentional movements of driven machine components during commissioning, operation,
maintenance, and repairs caused by, for example:
Hardware defects and/or software errors in the sensors, controllers, actuators, and
connection technology
Response times of the controller and drive
Operating and/or ambient conditions outside of the specification
Condensation / conductive contamination
Parameterization, programming, cabling, and installation errors
Use of radio devices / cellular phones in the immediate vicinity of the controller
External influences / damage
2. In the event of a fault, exceptionally high temperatures, including an open fire, as well as
emissions of light, noise, particles, gases, etc. can occur inside and outside the inverter,
for example:
Component malfunctions
Software errors
Operating and/or ambient conditions outside of the specification
External influences / damage
Inverters of the Open Type / IP20 degree of protection must be installed in a metal control
cabinet (or protected by another equivalent measure) such that the contact with fire inside
and outside the inverter is not possible.
3. Hazardous touch voltages caused by, for example:
Component malfunctions
Influence of electrostatic charging
Induction of voltages in moving motors
Operating and/or ambient conditions outside of the specification
Condensation / conductive contamination
External influences / damage
4. Electrical, magnetic and electromagnetic fields generated in operation that can pose a risk
to people with a pacemaker, implants or metal replacement joints, etc. if they are too close.
5. Release of environmental pollutants or emissions as a result of improper operation of the
system and/or failure to dispose of components safely and correctly.
Safety instructions
1.1 Fundamental safety instructions
TM15 / TM17 High Feature Terminal Modules
Manual, 11/2016 15

Other manuals for Siemens SIMOTION TM15

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTION TM15 and is the answer not in the manual?

Siemens SIMOTION TM15 Specifications

General IconGeneral
BrandSiemens
ModelSIMOTION TM15
CategoryTouch terminals
LanguageEnglish

Related product manuals