Commissioning
4.2 Commissioning with BOP-2 operator panel
SINAMICS G120C, FSD ... FSF inverters
60 Compact Operating Instructions, 11/2016, FW V4.7 SP6, A5E39339884B AA
Load gear unit maximum torque
p0544 Load gear unit gear ratio (absolute value) total,
numerator
p0545 Load gear unit gear ratio (absolute value) total,
p0546 Load gear unit output direction of rotation inver-
Inhibit automatic reference value calculation
Selecting technological units
1 referred, dimensionless
27 inch³/h 28 lb/s 29 lb/min
Reference quantity, technological units
Motor temperature sensor type
Bimetallic NC contact warning & timer
Motor temperature alarm threshold [°C]
Motor temperature fault threshold [°C]
Motor overtemperature response
0 No response, alarm only, no reduction of
I
max
Alarm with reduction of I
2 Alarm and fault, no reduction of I
max
12 Messages, no reduction of I
max
, temperature
t motor model thermal time constant [s]
Motor temperature model activation
.00 Activate motor
temperature mod-
.01 Activate motor
temperature mod-
.02 Activate motor
temperature mod-
.08 Activate motor
temperature mod-
.09 Activate motor
temperature mod-
el 2 expansions
.12 Motor tempera-
ture model 1 am-
bient temperature
p0613 Motor temperature model 1/3 ambient tempera-
Thermal resistor adaptation reduction factor
p0615 I
2
t motor model fault threshold [°C]
Motor ambient temperature [°C]
p0637 Q flux, flux gradient saturated [mH]
Motor operating hours, current [h]
Motor operating hours, maintenance interval [h]
r0720 CU number of inputs and outputs
r0722
CO/BO: CU digital inputs, status
DI 11 (terminals 3, 4) AI 0
CO/BO: CU digital inputs, status inverted
CU digital inputs debounce time [ms]
BI: CU signal source for terminal DO 0
NO: Terminal 19 / NC: Terminal 18
BI: CU signal source for terminal DO 1
CU, digital outputs status
CU, invert digital outputs