Commissioning
4.2 Commissioning with BOP-2 operator panel
SINAMICS G120C, FSD ... FSF inverters
60 Compact Operating Instructions, 11/2016, FW V4.7 SP6, A5E39339884B AA
No.
Description
p0543
Load gear unit maximum torque
p0544 Load gear unit gear ratio (absolute value) total,
numerator
p0545 Load gear unit gear ratio (absolute value) total,
nominator
p0546 Load gear unit output direction of rotation inver-
sion
p0550
Brake type
p0551
Brake code number
p0552
Brake maximum speed
p0553
Brake holding torque
p0554
Brake moment of inertia
p0573
Inhibit automatic reference value calculation
p0595
Selecting technological units
1
%
2
1 referred, dimensionless
3
bar
4
°C
5
Pa
6
ltr/s
7
m³/s
8
ltr/min
9
m³/min
10
ltr/h
11
m³/h
12
kg/s
13
kg/min
14
kg/h
15
t/min
16
t/h
17
N
18
kN
19
Nm
20
psi
21
°F
22
gallon/s
23
inch³/s
24
gallon/min
25
inch³/min
26
gallon/h
27 inch³/h 28 lb/s 29 lb/min
30
lb/h
31
lbf
32
lbf ft
33 K 34 rpm 35 parts/min
36
m/s
37
ft³/s
38
ft³/min
39
BTU/min
40
BTU/h
41
mbar
42
inch wg
43
ft wg
44
m wg
45
% r.h.
46
g/kg
47
ppm
p0596
Reference quantity, technological units
p0601
Motor temperature sensor type
0
No sensor
1
PTC warning & timer
2
KTY84
4
Bimetallic NC contact warning & timer
6
PT1000
p0604
Motor temperature alarm threshold [°C]
p0605
Motor temperature fault threshold [°C]
No.
Description
p0610
Motor overtemperature response
0 No response, alarm only, no reduction of
I
max
1
Alarm with reduction of I
max
and fault
2 Alarm and fault, no reduction of I
max
12 Messages, no reduction of I
max
, temperature
is saved
p0611
I
2
t motor model thermal time constant [s]
p0612
Motor temperature model activation
.00 Activate motor
temperature mod-
el 1 (I
2
t)
.01 Activate motor
temperature mod-
el 2
.02 Activate motor
temperature mod-
el 3
.08 Activate motor
temperature mod-
el 1 expansions
.09 Activate motor
temperature mod-
el 2 expansions
.12 Motor tempera-
ture model 1 am-
bient temperature
can be set
p0613 Motor temperature model 1/3 ambient tempera-
ture [°C]
p0614
Thermal resistor adaptation reduction factor
p0615 I
2
t motor model fault threshold [°C]
p0625
Motor ambient temperature [°C]
p0637 Q flux, flux gradient saturated [mH]
p0640
Current limit [A]
p0650
Motor operating hours, current [h]
p0651
Motor operating hours, maintenance interval [h]
r0720 CU number of inputs and outputs
r0722
CO/BO: CU digital inputs, status
.00
DI 0 (terminal 5)
.01
DI 1 (terminal 6)
.02
DI 2 (terminal 7)
.03
DI 3 (terminal 8)
.04
DI 4 (terminal 16)
.05
DI 5 (terminal 17)
.11
DI 11 (terminals 3, 4) AI 0
r0723
CO/BO: CU digital inputs, status inverted
p0724
CU digital inputs debounce time [ms]
p0730
BI: CU signal source for terminal DO 0
NO: Terminal 19 / NC: Terminal 18
p0731
BI: CU signal source for terminal DO 1
NO: Terminal 21
r0747
CU, digital outputs status
p0748
CU, invert digital outputs