EasyManua.ls Logo

Siemens SINAMICS G120C - Requirements for the protective conductor

Siemens SINAMICS G120C
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Commissioning
4.2 Commissioning with BOP-2 operator panel
SINAMICS G120C, FSD ... FSF inverters
Compact Operating Instructions, 11/2016, FW V4.7 SP6, A5E39339884B AA
69
No.
Description
r2132
CO: Actual alarm code
r2133 Fault value for float values
r2134
Alarm value for float values
r2135 CO/BO: Status word faults / alarms 2
r2136
Fault time removed in days
r2138
CO/BO: Control word, faults/alarms
r2139
CO/BO: Status word, faults/alarms 1
p2141
Speed threshold value 1 [rpm]
p2153
Speed actual value filter time constant [ms]
p2155
Speed threshold value 2 [rpm]
p2156
Switch-on delay comparison value reached [ms]
p2165 Load monitoring blocking monitoring upper
threshold [rpm]
p2168 Load monitoring blocking monitoring torque
threshold [Nm]
r2169
CO: Speed actual value smoothed signals [rpm]
p2170
Current threshold value [A]
p2171
Current threshold value reached delay time [ms]
p2172
DC-link voltage threshold [V]
p2174
Torque threshold value 1 [Nm]
p2191 Load monitoring torque threshold without load
[Nm]
p2194
Torque threshold value 2 [%]
p2195 Torque utilization switch-off delay [ms]
r2197
CO/BO: Status word monitoring functions 1
r2198 CO/BO: Status word monitoring 2
r2199
CO/BO: Status word monitoring 3
p2200
BI: Technology controller enable
p2201
CO: Techn. controller fixed value 1 [100 100%]
p2202
CO: Techn. controller fixed value 2 [100 ≙ 100%]
p2215 CO: Techn. controller fixed value 15 [100
100%]
p2216
Techn. controller fixed value selection method
1 Direct selection 2 Binary selection
p2220
BI: Techn. controller fixed value selection bit 0
p2221
BI: Techn. controller fixed value selection bit 1
p2222
BI: Techn. controller fixed value selection bit 2
p2223
BI: Techn. controller fixed value selection bit 3
r2224 CO: Techn. controller fixed value active [100 ≙
100%]
No.
Description
r2225 CO/BO: Techn. controller fixed value selection
status word
r2229 Techn. controller number currently
p2230 Techn. controller motorized potentiometer config-
uration
.00
Storage active
.02
Initial rounding active
.03 Non-volatile data save active for
p2230.0 = 1
.04
Ramp-function generator always active
r2231 Techn. controller motorized potentiometer set-
point memory
p2235 BI: Techn. controller motorized potentiometer
setpoint up
p2236 BI: Techn. controller motorized potentiometer
setpoint down
p2237 Techn. controller motorized potentiometer maxi-
mum value [%]
p2238 Techn. controller motorized potentiometer mini-
mum value [%]
p2240 Techn. controller motorized potentiometer start
value [%]
r2245 CO: Techn. controller motorized potentiometer
setpoint before RFG [100 100%]
p2247 Techn. controller motorized potentiometer ramp-
up time [s]
p2248 Techn. controller motorized potentiometer ramp-
down time [s]
r2250 CO: Techn. controller motorized potentiometer
setpoint after RFG [100 100%]
p2251
Techn. controller mode
0
Techn. controller as main speed setpoint
1 Techn. controller as additional speed set-
point
p2252
Technology controller configuration
.04 1 = ramp function generator (up/down) by-
pass deactivated
.05
1 = integrator for skip speeds active
.06 1 = do not display internal controller limita-
tion
p2253
CI: Techn. controller setpoint 1 [100 100%]
p2254
CI: Techn. controller setpoint 2 [100 ≙ 100%]
p2255
Techn. controller setpoint 1 scaling [100 ≙ 100%]
p2256 Techn. controller setpoint 2 scaling [100 ≙ 100%]
p2257
Techn. controller ramp-up time [s]
p2258
Techn. controller ramp-down time [s]

Other manuals for Siemens SINAMICS G120C