31
Function buttons
You can operate the motor using the function buttons. The HAND/AUTO button changes the command
source between the BOP-2 (HAND) and field-bus or terminal (AUTO). A symbol of a hand appears on
the screen to indicate that the HAND mode is active.
In the HAND mode, the ON and OFF buttons are enabled
In the AUTO mode, the ON and OFF buttons are disabled
If the HAND mode is active, pressing the HAND/AUTO button will switch the converter to the AUTO
mode
If the AUTO mode is active, pressing the HAND/AUTO button will switch the converter to the HAND
mode
Changing from the HAND to the AUTO mode is possible while the motor is running
A detailed list of the fault and
alarm messages can be found in
the “Parameter Manual: Control
Units – CU230P2” as a download
at: http://support.automation.
siemens.com/WW/view/
en/49946106
NOTE
Screen icons
The BOP-2 displays a number of icons at the left-hand side of the display to indicate the actual state
of the converter.
Command source, auto / hand
Converter status, operational
• JOG
Fault / alarms active
JOG