DC-link-side and machine-side actual current value acquisition
Line-side and machine-side overvoltage protection with spark-gap-free metal-oxide surge
arresters
DC link reactor for decoupling the line-side converter from the motor-side converter
Power cables connected from below
3.3.2 Power unit components
The diagram below shows an example of the typical components of a starting converter for a
6/6-pulse drive system:
Circuit breaker
Surge suppressor
Line-side converter
Air-cooled DC link reactor, installed in a cabinet
Motor-side converter
Motor voltage sensing (U
M
sensing)
Current transformer in the DC link
Converter transformer
Synchronizing transformer or converter
Figure 3-1 Components of a starting converter for a 6/6-pulse drive system
3.3.2.1 Design of the thyristor stack
1 or 2 thyristor stacks are used for a 6‑pulse bridge. They differ in the number of pick-offs from
the heat sinks. The thyristor stacks are equipped with various thyristors and corresponding RC
(resistor, capacitor) circuitry. Six thyristors are braced in one clamped thyristor assembly.