Controlled Power Module (CPM60.1)
A5E03975175-002, 04/2014
11
Order No. : 6SL3210-
5CC14-0UA0
5CC16-0UA0
5CC17-0UA0
5CC21-0UA0
Transportation -40 ℃ to 70 ℃
Storage -25 ℃ to 55 ℃
Relative humidity < 95 %
Vibration resistance Operation ≤ 1 G (0.075 mm)
Transport & storage ≤ 2 G (7.5 mm)
Installation altitude < 1,000 m above sea level: without power derating;
1,000 to 2,000 m: with power derating (derated to 80%)
Protection class IP20
Outline dimensions (W x H x D) 106 x 226 x 200
mm
106 x 226 x 200
mm
106 x 226 x 200
mm
123 x 226 x 200
mm
For technical data of the motor, please refer to the Motor Specification delivered with the motor.
Technical data for transformer
Recommended transformer type
380 V/220 V SG series 3AC isolating transformer
Supply voltage 3 AC 380 V/220 V
50/60 Hz
Connection group Y/Y-12
Impedance voltage (Uk%) 4
No-load current (%) For a transformer =< 1.0 kVA, the no-load current < 18%
For a transformer > 1.0 kVA, the no-load current < 14%
Power selection (for standard
turning/milling machines)
Possible motor combination Transformer power (apparent power)
4 Nm 1.0 kVA
6 Nm 1.5 kVA
7.7 Nm 2.0 kVA
10 Nm 2.5 kVA
4 Nm + 4 Nm 1.5 kVA
4 Nm + 6 Nm 1.5 kVA
4 Nm + 7.7 Nm 1.5 kVA
4 Nm + 10 Nm 2.0 kVA
6 Nm + 6 Nm 2.0 kVA
6 Nm + 7.7 Nm 2.0 kVA
6 Nm + 10 Nm 2.5 kVA
7.7 Nm + 7.7 Nm 2.0 kVA