PLC Subroutines Manual
48 6FC5397-0FP40-0BA0, 08/2013
Local variable definition
Table 3-17 Inputs
ASUP1_trigger BOOL Calling the ASUP1, rising edge active
ASUP2_trigger BOOL Calling the ASUP1, rising edge active
Table 3-18 Outputs
ASUP1Run BOOL Running state of the ASUP1
ASUP2Run BOOL Running state of the ASUP2
Err1 BOOL ASUP1 execution error
Err2 BOOL ASUP2 execution error
Occupied global variables
IniASUP1 M229.0 Mark of ASUP1 initialization
IniASUP2 M229.1 Mark of ASUP2 initialization
Relevant PLC machine data
None
Example for calling subroutine 46
Subroutine 47 - PLC_Select_PP (PLC selects a subroutine)
Purpose
Subroutine 47 is used to select a part program.
You firstly need to create a PLC program-calling table, and assign a program index to each part program in this table. In
subroutine 47 you can assign DB1700.DBB1000 to the "Program index" to select the corresponding part program.
Local variable definition
Table 3-19 Inputs
PP_num BOOL The index for a part program