Additional information
Additional information on how to commission an NX component is provided in:
● Commissioning Manual IBN CNC: NCK, PLC, Drive
See also
Connecting digital inputs/outputs (Page 80)
11.1.5 Technical Data
Table 11-9 Safety-related data
Protection class III
Degree of protection to EN 60529 IPXXB
Approvals CE, cULus
Pollution degree 2
Cooling Open-circuit ventilation
Mounting position Vertical
PE/ground connection at the housing with M5 screw Torx / 3 Nm
Table 11-10 Electrical and mechanical data
Input voltage 24 V DC (20.4 – 28.8)
Current drain (without DRIVE-CLiQ and digital outputs) 0.3 A
Max. permitted output current 3.35 A
Power loss 15 W
Dimensions WxHxD (with spacers) 25 x 414 x 272 mm
Weight 2.58 kg
11.2 PP 72/48D PN
11.2.1 Description
Characteristics
I/O module PP 72/48D PN is a simple module (without a separate housing) for connecting
digital input/outputs as part of an automation system based on PROFINET IO.
Connectable components
11.2 PP 72/48D PN
NCU 1760
Equipment Manual, 02/2020, A5E45627861B AB 103