Functional restrictions
There are currently still functional restrictions compared with the status described here. For
details, refer to the document "SINUMERIK ONE VCC and supplementary components
"blacklist/whitelist".
2.2 System configuration
SINUMERIK ONE combines CNC, HMI, PLC, closed-loop control and communication tasks
within a single NCU (Numerical Control Unit).
Components
For operation, programming, and visualization purposes, the corresponding operating software
is already integrated into the CNC software for the NCU and therefore runs on the high-
performance NCU multi-processor module. A SIMATIC IPC für SINUMERIK can be used for
increased performance in the operating area.
Up to four distributed OPs can be operated on one NCU/PCU. The operator panel can be
installed as a Thin Client at a distance of up to 100 m.
The following components can be connected to the NCU:
SINUMERIK operator panel front with TCU 30.3 / SIMATIC IPC for SINUMERIK and
Machine Control Panel / Machine Push Button Panel
SIMATIC Thin Client (as of firmware V2.0.1)
SIMATIC CE panel
SINUMERIK handheld units
Distributed PLC I/O
SIMATIC
e.g. ET200SP and ET200MP
SINUMERIK via PROFIBUS DP:
e.g. SINUMERIK I/O module PP 72/48D
SINUMERIK via PROFINET IO:
SINUMERIK I/O modules PP 72/48D PN and PP 72/48D 2/2A PN
SINAMICS S120 drive system
Feed motors, main spindle motors and direct-drive motors in synchronous and
asynchronous design:
Feed motors: 1FT, 1FK
Main spindle motors: 1PH, 1FE, 2SP1
Direct-drive motors: 1FN3, 1FW6
System overview
2.2 System configuration
NCU 1760
18 Equipment Manual, 02/2020, A5E45627861B AB