1 2 3 4 5 6 7 8 9 10 Default device name
on on on off on on on off pp72x48pn119
off on on off on on on off pp72x48pn118
on off on off on on on off pp72x48pn117
off off on off on on on off pp72x48pn116
on on off off on on on off pp72x48pn115
off on off off on on on off pp72x48pn114
on off off off on on on off pp72x48pn113
off off off off on on on off pp72x48pn112
x x x x x x x x "
on on on on off off off off pp72x48pn15
off on on on off off off off pp72x48pn14
on off on on off off off off pp72x48pn13
off off on on off off off off pp72x48pn12
on on off on off off off off pp72x48pn11
off on off on off off off off pp72x48pn10
on off off on off off off off pp72x48pn9
off off off on off off off off pp72x48pn8
on on on off off off off off pp72x48pn7
off on on off off off off off pp72x48pn6
on off on off off off off off pp72x48pn5
off off on off off off off off pp72x48pn4
on on off off off off off off pp72x48pn3
off on off off off off off off pp72x48pn2
on off off off off off off off pp72x48pn1
off off off off off off off off pp72x48pn
Note
A newly set PROFINET address will only come into effect after power OFF/ON.
11.2.3.4 X111, X222 and X333 digital inputs/outputs
Cable specification
Connectors: 50-pin ribbon cable connectors
50-pin insulation displacement connectors with cable grip, ribbon cables and terminal
converters
are required for connecting digital inputs and outputs.
The required connecting cables (ribbon cables) must be provided by the user
.
Max. cable length: 30 m
Connectable components
11.2 PP 72/48D PN
NCU 1760
Equipment Manual, 02/2020, A5E45627861B AB 113