11.3.4 Connecting
11.3.4.1 Interface overview
3RZHUVXSSO\
3RZHUVXSSO\
7HUPLQDOVWULSFRQYHUWHU
5LEERQFDEOH
&RQQHFWLRQFDEOHPD[LPXP
P
);'&
'LJLWDO,2
$QDORJ,2
3RUWDQG
33'$31
9'&
352),1(7;
;
;
;
;
;
1&8[
33'31
33'$31
0&3&&31
Figure 11-14 Connection options of the PP 72/48D 2/2A PN I/O module
Interface overview
Table 11-33 Interfaces of the PP 72/48D 2/2A PN I/O module
Interface Designation Type
Power supply connection X1 Screw-terminal block
PROFINET IO X2 (ports 1 and 2) Socket
Analog inputs/outputs X3 Terminal block
PROFINET address S1 DIP switch
Digital input/outputs 1 X111 Ribbon cable connector
Digital input/outputs 2 X222 Ribbon cable connector
Digital input/outputs 3 X333 Ribbon cable connector
The following abbreviations are used:
Signal type Meaning
I Input
O Output
B Bidirectional
Connectable components
11.3 PP 72/48D PN 2/2A PN
NCU 1760
126 Equipment Manual, 02/2020, A5E45627861B AB