Appendix
A.8 Information List
SIPROTEC, 7SD5, Manual
C53000-G1176-C169-5, Release date 02.2011
724
3176 Diff: Fault detection L1 (only) (Diff
Flt. 1p.L1)
Diff. Prot OUT * * * LED BO
3177 Diff: Fault detection L1E (Diff Flt.
L1E)
Diff. Prot OUT * * * LED BO
3178 Diff: Fault detection L2 (only) (Diff
Flt. 1p.L2)
Diff. Prot OUT * * * LED BO
3179 Diff: Fault detection L2E (Diff Flt.
L2E)
Diff. Prot OUT * * * LED BO
3180 Diff: Fault detection L12 (Diff Flt.
L12)
Diff. Prot OUT * * * LED BO
3181 Diff: Fault detection L12E (Diff Flt.
L12E)
Diff. Prot OUT * * * LED BO
3182 Diff: Fault detection L3 (only) (Diff
Flt. 1p.L3)
Diff. Prot OUT * * * LED BO
3183 Diff: Fault detection L3E (Diff Flt.
L3E)
Diff. Prot OUT * * * LED BO
3184 Diff: Fault detection L31 (Diff Flt.
L31)
Diff. Prot OUT * * * LED BO
3185 Diff: Fault detection L31E (Diff Flt.
L31E)
Diff. Prot OUT * * * LED BO
3186 Diff: Fault detection L23 (Diff Flt.
L23)
Diff. Prot OUT * * * LED BO
3187 Diff: Fault detection L23E (Diff Flt.
L23E)
Diff. Prot OUT * * * LED BO
3188 Diff: Fault detection L123 (Diff Flt.
L123)
Diff. Prot OUT * * * LED BO
3189 Diff: Fault detection L123E (Diff
Flt. L123E)
Diff. Prot OUT * * * LED BO
3190 Diff: Set Teststate of Diff. protec-
tion (Test Diff.)
Diff. Prot IntSP on
off
**LEDFC
TN
BO 92 106 1 Yes
3191 Diff: Set Commissioning state of
Diff. (Comm. Diff)
Diff. Prot IntSP on
off
**LEDFC
TN
BO 92 107 1 Yes
3192 Diff: Remote relay in Teststate
(TestDiff.remote)
Diff. Prot OUT on
off
* * LED BO 92 108 1 Yes
3193 Diff: Commissioning state is
active (Comm.Diff act.)
Diff. Prot OUT on
off
* * LED BO 92 109 1 Yes
3197 Diff: >Set Teststate of Diff. protec-
tion (>Test Diff. ON)
Diff. Prot SP on
off
**LEDBIBO
3198 Diff: >Reset Teststate of Diff.
protec. (>Test Diff. OFF)
Diff. Prot SP on
off
**LEDBIBO
3199 Diff: Teststate of Diff. prot.
ON/OFF (Test Diff.ONoff)
Diff. Prot IntSP on
off
**LEDBO
3200 Diff: Teststate ON/OFF via BI
(TestDiffONoffBI)
Diff. Prot IntSP on
off
**LEDBO
3215 Incompatible Firmware Versions
(Wrong Firmware)
Prot. Interface OUT on * LED BO
3217 Prot Int 1: Own Datas received
(PI1 Data reflec)
Prot. Interface OUT on
off
* LED BO
3218 Prot Int 2: Own Datas received
(PI2 Data reflec)
Prot. Interface OUT on
off
* LED BO
3227 >Prot Int 1: Transmitter is
switched off (>PI1 light off)
Prot. Interface SP on
off
**LEDBIBO
3228 >Prot Int 2: Transmitter is
switched off (>PI2 light off)
Prot. Interface SP on
off
**LEDBIBO
3229 Prot Int 1: Reception of faulty data
(PI1 Data fault)
Prot. Interface OUT on
off
* * LED BO 93 135 1 Yes
No. Description Function Type
of In-
for-
matio
n
Log Buffers Configurable in Matrix IEC 60870-5-103
Event Log ON/OFF
Trip (Fault) Log On/Off
Ground Fault Log ON/OFF
Marked in Oscill. Record
LED
Binary Input
Function Key
Relay
Chatter Suppression
Type
Information Number
Data Unit
General Interrogation

Table of Contents

Related product manuals