SITRANS F M MAGFLO
®®
®®
®
19
SFIDK.PS.026.E5.02
ENGLISH
Type Sensor with flanges
Nominal size
mm
DN 15 - DN 2000
Temperature of medium
1
) Temperature classification
Liner:
T3 + T4 T5 T6
Neoprene (standard) 0 to 70°C 0 to 70°C 0 to 70°C
EPDM
2
) −10 to 95°C −10 to 90°C −10-75°C
Linatex
®
rubber −20 to 70°C −20 to 70°C −20 to 70°C
Ebonite
2
) 0 to 95°C 0 to 90°C 0 to 75°C
PTFE −20 to 100°C −20 to 90°C −20 to 75°C
Ambient temperature Remote transmitter: −20°C to 60°C
Operating pressure
3
)
[[
[[
[abs.bar
]]
]]
]
Liner:
Neoprene 0.01 to 100 bar
EPDM 0.01 to 40 bar
Linatex
®
0.01 to 40 bar
Ebonite 0.01 to 100 bar
PTFE teflon:
DN 15 to 600: 0.3 to 40 bar
Excitation frequency DN 15 - 65: 6.25 Hz
DN 80/100: 3.125 Hz
DN 125 - 300: 1.5625
Hz
DN 350 - 1200: 3.125 Hz
Enclosure rating
Standard
IP67 to EN 60529 (NEMA 4X) (1 m w.g for 30 min.)
Option
IP68 to EN 60529 (NEMA 6) (10 m w.g. cont.)
Cable entries 4 Pg 13.5
Mechanical load 18-1000 Hz random, 3.17 G rms in all directions to EN 60068-2-36
Test pressure 1.5 × PN
Flanges
Standard
DN 15-50: PN 40
EN 1092-1:2001
4
) DN 65-150: PN 16
Rased face
DN 200-1000: PN 10
DN 1100 -2000: PN 6
Option
DN 65-1000: PN 6
DN 1200-2000: PN 10
DN 200-2000: PN 16
DN 200-600: PN 25
DN 65-600: PN 40
DN 50-400 PN 63
DN 25-350 PN 100
ANSI B 16.5 (∼BS 1560) 3/4"-24": Class 150 (20 bar)
3/4"-24": Class 300 (50 bar)
AS 2129 3/4"-48": Table D/E
AS 4087 PN 16 (DN 50 - 1200, 14 bar)
PN 21 (DN 50 - 600, 21 bar)
PN 35 (DN 50 - 600, 35 bar)
AWWA C-207 28"-78": Class D (10 bar)
Electrodes
Standard
AISI 316 Ti (1.4571)
Option
Hastelloy C-276, Platinum / Iridium, Titanium, AISI 316 Ti Ceramic
Coated, Tantalum
PE - electrodes
Standard
As measuring electrodes (except PTFE)
Measuring pipe
Standard
AISI 304 (1.4301)
Option
AISI 316 L (1.4404)
Flange and
Standard
Carbon steel
housing material
Corrosion-resistant two-component coating (min. 150 µm)
Option
AISI 304 (1.4301) flanges and carbon steel housing.
Coating as above
Option
AISI 316 L (1.4404) flanges and housing
Ex-approval See section 2.7; I
s
interface data see section 2.5
Conforms to PED, LVD, EMC PED - 97/23EC, LVD - 73/23 EEC +
amendment 93/68/EEC, EMC - 89/336 EEX
1
) The maximum fluid temperature may be further limited by the approval temperature ratings, see section 2.7
2
) With WRC (Water Research Council, UK) approval
3
) Maximum operating pressure decreases with increasing operating temperature and with stainless steel flanges
4
) EN 1092-1, DIN 2501 & BS 4504 have the same mating dimensions
4.2.2 Sensor MAG 3100 Ex
4. Technical data