EasyManua.ls Logo

Siemens SITRANS LVS100 - Specifications

Siemens SITRANS LVS100
116 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7ML19985FT63 SITRANS LVS100/200 – INSTRUCTION MANUAL Page EN-5
mmmmm
English
Specifications
Power
LVS100
19 to 230 V AC,
10 %, 50 to 60 Hz, 22 VA / 19 to 40 V DC, 10 %, 2 W
LVS200
19 to 230 V AC, +10 %, 50 to 60 Hz, 1.8 VA / 19 to 55 V DC, +10 %, 1.5 W
18 to 50 V DC 3-wire PNP
7 to 9 V DC (requires NAMUR switch amplifier) NAMUR IEC 60947-506, 2-wire
8/16 mA or 4 to 20 mA; 12.5 to 35 V DC, 2-wire
Performance
Measuring frequency
LVS100
standard approx. 200 Hz
LVS200
standard approx. 125 Hz
liquid/solid interface version approx. 350 Hz
enhanced sensitivity option approx. 90 Hz
Signal delay
probe uncovered to covered approx. 1 second
probe covered to uncovered approx. 1 to 2 seconds
Relay delay (DPDT version) (LVS200)
adjustable up to 30 seconds
Sensitivity
high or low, switch selectable
Minimum material density
LVS100
standard version approx. 30 g/l (1.9 lb/ft
3
)
LVS200
standard version approx. 20 g/l (1.2 lb/ft³)
standard version with low density fork approx. 5 g/l (0.3 lb/ft³)
liquid/solid interface version approx. 50 g/l (3 lb/ft³)
Note: Siemens Milltronics makes every attempt to ensure the accuracy of these
specifications but reserves the right to change them at any time.