Operating Manual SIGMA 4-15C, page 42 of 95
03/06
4.1.1 Start-key
This key can be used for the following:
starting centrifuge operation,
terminating a previously started deceleration process and restarting
centrifuge,
shifting into short-run at preselected speed. Pressing Start-key continuously
for longer than one second leads to acceleration to the maximum speed with
the maximum acceleration curve and after release deceleration with the
maximum deceleration curve.
The centrifuge can be started when
the lid is closed
the Start-key is illuminated.
4.1.2 Stop-key
This key can be used
to early terminate a run: The centrifuge decelerates with the preset curve to a
complete stop. Deceleration can be terminated by pressing the Start-key
again.
to carry out a faststop: Push Start-key for longer than one second. The
centrifuge decelerates with the maximum deceleration curve.
4.1.3 Lid-key
This key is used to open the lid. This can only be executed if
the centrifuge has come to a complete stop
the Lid-key is illuminated.
4.1.4 Knob
This knob can be used for selecting and alterating parameters and figures/
numbers.