SAFETY REQUIREMENTS
01
WARNINGS/PRECAUTIONS
02
At any stage of operation on the optical fiber fusion splicer, you must take the following general safety
precautions. Not take these warnings and precautions or not comply with the warnings which described in this
manual, would violate the fusion splicer design, manufacture and use of safety standards. My company does not
assume any responsibility for the consequences of breaching these requirements
for users caused!
Operation environment and Power
Fusion splicer operation, storage environment and working power requirements
Operating temperature: 0+40 Limit temperature: -10℃~+50
Operating humidity: 95%RH or less (no condensation) Maximum wind speed: 15m/s
Storage conditions:-20℃~+60( no condensation)
Before turning on the power, please make sure that the power supply can match its voltage,and that all safety
measures are taken.
Do not use the fusion splicer in explosive environments
Do not use the fusion splicer in the presence of flammable gases or fumes
Do not attempt to disassemble any of the components of fusion splicer
In addition to the statements in this manual to allow user-replaceable parts, please do not attempt to disassemble
any of the components of fusion splicer. Replacement parts and internal adjustments can only be commissioned by
authorized service personnel.
AC/DC Adapter
The Output Characteristics Of The Power Adapter Must Meet The Following Quirements.
Voltage: 12V-14V; Current: 2A (output voltage of original adapter: 13.5v, output current 4.8A)
Polarity: Center Is Positive;The fiber fusion splicer will be damaged or unable to charge if uses inappropriate adapter
to output voltage and current .Using Higher Voltage Will Cause Damage To The Fusion Splicer. AC /DC Power
Adapter Input AC Voltage Of 100-240v,50/60hz, If Input Voltage Exceeds This Range May Cause Permanent
Damage To The Adapter!
Internal Lithium Battery
There Is A Lithium-ion Battery Cells In The Fusion Splicer, The Use Of Other Batteries May Damage The
Fusion Splicer And Jeopardize Personal Safety.
For Safety Sake, Lithium Battery Pack Can Not Be Disassembled To Prevent Short Circuits; Do Not Crash
Battery, Do Not Let The Battery Close To A Fire Or An Excessive Heat To Prevent Lithium Battery Explosion.
Violation of the above operation may cause lithium battery explosion, endangering the personal safety of users.
Notice:
1.When the battery is placed for a long time, it is easy to enter into the dormancy state. At this time, the capacity is
lower than the normal value, and the service time is also shortened. However, the battery can be activated and its
normal capacity can be restored after only 2-3 normal charging and discharging cycles. Lithium batteries have little
memory effect and can be recharged at any time.
2.Lithium batteries exist self-discharge phenomenon, a long time of unused batteries will be in the state of low voltage
because of self-discharge.A long period of low voltage will damage the internal structure of the battery and shorten the
battery life.Therefore, unused batteries should be charged at least once a month, pay attention to the display of 2 or 3
bars of electricity can be charged, should not be full;In daily use, try to charge in the battery display more than one grid,
do not run out of power to charge
3.Do not use the machine for a long time, please take out the battery and store it separately. The temperature range of
long-term storage (storage time over 6 months) of the battery is 0~40. The temperature range of short-term battery

Other manuals for SIGNAL FIRE AI-9

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SIGNAL FIRE AI-9 and is the answer not in the manual?

SIGNAL FIRE AI-9 Specifications

General IconGeneral
CategoryFusion Splicer
Fiber AlignmentCore Alignment
Cutting Length8-16mm
InterfaceUSB
Communication InterfaceUSB
Applicable FibersSM, MM, DS, NZDS
Splice Loss0.02dB (SM)
Return Loss>60dB
Typical Splice Time9 seconds
Fiber Diameter80-150μm
Power SupplyAC 100-240V
Monitor Fiber View4.3 inch LCD
Operating Condition-10°C to 50°C
Storage ConditionHumidity: 0-95%, Temperature: -20℃~+75℃