keep the button
t
pressed and scroll through the parameters
until reaching parameter "03"
press the button
>
and select "1" (LPG)
Procedure which MUST be carried out after:
the nozzles for gas conversion
changing the gas valve following a fault
changing the the electronic board following a fault
electrode
fan
burner
go into the parameter section (if not already there) by press-
ing the buttons
r
and
t
(for approximately 5 seconds) at the
same time until
"PAR 01"
(parameter number) and the value
set (0-4) appears on the display
keep the button
t
pressed and scroll through the parameters
until reaching parameter
"PAR 49"
press and hold the button
>
to set the value
at "49"
the modified value will be stored automatically
keep the button
t
pressed and scroll through the parameters
until reaching parameter
"PAR 70"
press the button
>
to set the value
at "5"
the modified value will be stored automatically
exit the parameter section by pressing and holding down the
buttons
r
and
t
at the same time
(approximately 5 seconds)
until the delivery temperature is displayed.
m
IMPORTANT
To complete this task the user
MUST
carry out the fol-
lowing procedure.
Adjusting maximum gas pr
essure:
press the button
y
until "SUMMER" mode
l
has been se-
lected
press button
r
and set the DOMESTIC HOT WATER SET to
maximum using the button
>
press and hold down the buttons
>
and
y
at the same time
for approximately 6 seconds until the message
"Au"
appears on
the display alternating with
"to"
open one or more than one hot water tap
the boiler will start up and the message
"P01"
will appear on
the display (Adjusting maximum gas pressure)
press the buttons
>
or
<
until the pressure value indicated in
the table appears on the pressure gauge
once the value indicated in the table has been reached, press
the button
y
for approximately 2 seconds to confirm the val-
ue which will then flash once.