EasyManua.ls Logo

Sime UNIQA REVOLUTION - Detailed Technical Features; Boiler Performance and Specifications

Sime UNIQA REVOLUTION
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15
5.5 Technical features
DESCRIPTION
UNIQA REVOLUTION
CERTIFICATIONS
Country of intended installation IT – EN – ES
Fuel G20 - G30/G31
PIN number 1312CS6207
Category II2H3+
Appliance classification C10 - C12 - C12X - C32 - C32X - C42 - C42X - C52 - C52X - C82 - C82X
Class NO
x
(*) 6 (< 56 mg/kWh)
HEATING PERFORMANCE
HEAT INPUT (**)
Nominal flow (Qn max) kW 24,5
Minimum flow (Qn min) kW 10
HEAT OUTPUT
Nominal (80-60°C) (P
n
max) kW 22,9
Minimum power (80-60°C) (G20/G30/G31) (Pn min) kW 8,9
EFFICIENCY
Max useful efficiency (80-60°C) % 93,4
Min useful efficiency (80-60°C) % 89,2
Useful efficiency at 30% of load (40-30°C) % 108,8
Losses after shutdown at 50°C W 168,0
DOMESTIC HOT WATER PERFORMANCE
Nominal heat input (Qnw max) kW 24,5
Minimum heat input (Qnw min) kW 10,0
Specific D.H.W. flow rate ∆T 30°C (EN 13203) l/min 10,6
Continuous D.H.W. flow rate (∆T 25°C / ∆T 35°C) l/min 12,9 / 9,2
Minimum D.H.W. flow rate l/min 2
Max (PMW) / Min Pressure
bar 7 / 0,5
kPa 700 / 50
ENERGY PERFORMANCE
HEATING
Heating seasonal energy efficiency class B
Heating seasonal energy efficiency % 86
Sound power dB(A) 54
DOMESTIC HOT WATER
Domestic hot water energy efficiency class A
Domestic hot water energy efficiency % 81
Stated domestic hot water profile load XL
ELECTRICAL SPECIFICATIONS
Power supply voltage V 230
Frequency Hz 50
Absorbed electrical power Qn max W 105
Absorbed electrical power Qn min W 334
Absorbed electrical power in stand-by W 3
Electrical protection degree IP X5D
Maximum absorbed current A 2,4
COMBUSTION DATA
Smoke temperature at Max/Min flow (80-60°C) °C 106 / 75
Smoke flow Max/Min g/s 29,7 / 15,8
CO
2
at Max/Min (G20) flow rate with separate chimneys % 3,3 / 2,5
CO (0% of O
2
) ppm 120
NOx measured mg/kWh 38
NOZZLES  GAS
Number of nozzles No. 26
Nozzle diameter (G20) mm 0,85
Nozzle diameter (G30-G31) mm 0,50
Gas consumption at Max/Min flow rate (G20) m
3
/h 2,59 / 1,06
Gas consumption at Max/Min flow rate (G30) kg/h 1,93 / 0,79
Gas consumption at Max/Min flow rate (G31) kg/h 1,90 / 0,78
Gas supply pressure (G20/G30/G31)
kg/h 20 / 29 / 37
kPa 2 / 2,9 / 3,7
TEMPERATURE  PRESSURE
Max operating temperature (T max) °C 85
Heating adjustment range °C 20 ÷ 80
Domestic hot water adjustment range °C 10 ÷ 60
Max operating pressure (PMS)
bar 3
kPa 300
Water content in boiler l 3,35
R134a refrigerant gas content g 250
(*) NOx class according to UNI EN 15502-1:2015
(**) Heat input calculated using the lower heat output (Hi)
Lower Heat Output (Hi)
G20 Hi.
9.45 kW/m
3
(15°C, 1013 mbar) -
G30 Hi.
12.68 kW/kg (15°C, 1013 mbar) -
G31 Hi.
12.87 kW/kg (15°C, 1013 mbar)

Table of Contents