PAGE | 15
Error
Code
Description Recommendation Action 1 Action 2
0x1000D PA soft over heat The power amplier temperature is too
high. Restart the pedestal, wait 5 minutes
and let the pedestal work for at least 1 hour.
Does the alarm continue?
Yes Check the heat
pipe connection
Refer to “Heat
pipe” on page
18.
Replace the
transceiver
module.
0x1000E PA hard over heat No Finished
0x1000F GW data path
error
FPGA error. Do a system restart, does the
system operate properly?
Yes Finished
No Replace the
transceiver
module.
0x10010 PSU overheat The power supply’s temperature is too hot,
restart the pedestal, wait 5 minutes and let
the pedestal work for at least 1 hour. Does
the alarm continue?
Yes Replace the
transceiver
module.
No Finished
0x10011 PSU voltage The power supply’s voltage is or are wrong,
restart the pedestal and try again. Does the
alarm continue?
Yes Replace the
transceiver
module.
No Finished
0x10012 PSU power The power supply’s power is too high,
restart the pedestal and try again.
Yes Replace the
transceiver
module.
Does the alarm continue? No Finished
0x10013 PSU hardware
fault
The power supply is in fault, restart the
pedestal and try again.
Yes Replace the
transceiver
module.
Does the alarm continue? No Finished
0x10017 Scanner fail This indicates a mismatch between the
radar’s congured scanner-type/model and
it’s actual hardware.
Yes Replace the
transceiver
module.
Contact service.
No Finished
0x1001B Safety mode The safety switch is in position “0”, change
it to position “1” (pedestal active). Does the
alarm continue?
Yes Replace the
transceiver
module.
Contact service.
No Finished
0x1001D Install cache
mismatch
This indicates hardware or software
conguration information cached by
the radar no longer matches the actual
hardware or current conguration. Does the
alarm continue?
Yes Contact service.
No Finished
0x1001F Motor driver error The electronic part that controls the motor
is faulty. Restart the pedestal. Does the
alarm continue?
Yes Replace the
transceiver
module.
Replace the
motor and gear.
No Finished
0x10020 PA hard
overcurrent
The power amplier current is too high,
restart the pedestal. Does the alarm
continue?
Yes Replace the
transceiver
module.
No Finished