This setting is only applicable if the yellow wire is used for power control.
Set to slave if the yellow wire is connected to ignition or to a stand-alone switch that
applies 12 V/24 V
Set to master to make this device turn other devices connected to the master slave bus on
and off
When a master unit is turned on or off, all units connected to the same master slave bus
turns on or off.
While a master unit is on, a slave unit cannot be turned off.
If no master unit is turned on, slave units can be turned on or off individually.
Advanced
Is a dialog for advanced setting and how your system displays various user interface
information.
Enable and disable features
It is possible to enable or disable features that are not automatically enabled or disabled by
the system.
Alarms settings
Settings
List of all available alarm options in the system, with current settings.
From this list you can activate, deactivate and change alarm limits.
Siren enable
The Siren enabled option must be set in order for the unit to activate the buzzer when an
alarm condition arises.
Its setting also determines the operation of the external alarm output.
Radar settings
Ú
Note: The installation can vary depending on the radar. Follow the installation and setup
instructions supplied with the radar.
Use the Radar Installation dialog to setup the radar.
Software setup | NSO-evo3 Installation Manual
21