Tighten the bolts. Recheck the
alignment to make sure that you do not
move the bearing housing.
The grinding head is aligned at the
factory and should only be adjusted if you
are sure it is out of alignment.
With the grinding head disengaged
and the grinding stone removed (see
Section 6.1), mount the dial indicator so
that the tip touches the front of the shaft.
Move the grinding head back and forth
and read the difference on the dial
indicator.