4.4 Communication with Android GCS through UDP
4.4.1 QGroundControl
1. In “SIYI TX” app, go to “Datalink”, and choose “UDP” in “Connection”, “PIX / PX4
/ Ardupilot” in “Flight Controller”, and match the baud rate with the flight controller
TELEM port’s.
2. Run QGroundControl, go to “Application Settings - Comm Links” page, and “Add”
a new connection. Name it as “UDP”.
3. Set the connection “Type” as UDP”, “Port” as “19856”, “Server Addresses” as
“192.168.144.12” and “Add Server”.