EN
KFG/KFGS pump malfunctions
Fault
Category Possible cause Rectification
Pump Agitator in
grease reservoir does
not rotate during the
activated pump cycle
(CONTACT mode).
Malfunction
Mechanical damage,
e.g., motor defective
Electrical connection interrupted
• Replace pump
- Loosen main line at outlet of pressure regulating valve.
- Loosen electrical connection.
- Loosen three fastening screws.
- Remove defective pump.
- Mount new pump and connect lubrication line
and electrical cable.
• Perform commissioning and functional inspection.
• Be sure the interval and contact times are correct.
• Check or replace fuse.
• Check electrical connections
• Check cable set for damage.
Pump does not
function when the
key is pressed,
although all electrical
connections are ok.
Malfunction
Electrical control has failed.
Pump drive/motor is defective.
Lubricant level in reservoir is
below minimum.
Agitator does not rotate.
• Check fuse
• Replace pump
• Fill lubricant reservoir to "max."
• Replace pump element
Note: metering is indicated by grooves.
15.1.8 Malfunctions on KFG/KFGS pump units
15. Operational and pump faults
KFGS
KFG

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SKF KFG and is the answer not in the manual?

SKF KFG Specifications

General IconGeneral
BrandSKF
ModelKFG
CategoryWater Pump
LanguageEnglish

Related product manuals