EasyManuals Logo

SKF KFG User Manual

SKF KFG
116 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #20 background imageLoading...
Page #20 background image
Page 20
EN
KFGS
KFG
KFGC
Pump elements
Delivery rate
1
) Number of grooves Max. permiss. oper. pressure Order No.
[cm
3
/min] [bar]
5.0 0 200 KFG1.U0
2.5 1 300 KFG1.U1
1.8 2 300 KFG1.U2
1.3 3 300 KFG1.U3
0.8 4 300 KFG1.U4
1) The values given here apply for a temperature of 20 °C, back pressure of 50 bar and greases of NLGI Grade 2.
The 5.0 cm
3
/min pump element is preferred for use in single-line centralized lubrication systems.
M20x1,5
M14x1,5
KFG pump element with constant delivery rate, without
pressure regulating valve
KFG pump element with constant delivery rate, without
pressure regulating valve
4.3.4 Deliverable pump elements
The pump element must be ordered according
to the required delivery rate (see Pump ele-
ments table).
2 1 3
Connection for pump elements
1 Screw plug
2 Pipe connector
3 Pump element with
pressure regulating valve
Connection for pump elements
Marking grooves, see table,
column for number of grooves
Assembly instructions