24
Flashes Max pressurization time (minutes)
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
9 9
10 10
Setting of pressurization time changes from smaller to bigger by pressing the button. After
reaching the biggest reading unit, start again from the beginning of the table.
Return from setting mode of pressurization time and save a new setting by pressing the
SET-button for 5 seconds until all three LED-signals are lit.
Note To exit setting mode without saving settings, switch off operating voltage
for Multilube for a moment.
Setting of the lubrication system
Press SET-button for 15 seconds in normal operation mode until the LED-signals 1 and 2
begin to flash quickly.
Now you can select the lubrication system. Single- or dual-line lubrication system can be
selected.
When the single-line system is selected P LED-signal flashes once and alternatively when
the dual-line system is selected P LED-signal flashes twice before a pause for 2 seconds.
The system can be selected with the button.
Return from setting mode of lubrication system and save a new setting by pressing the
SET-button for 5 seconds until all three LED-signals are lit
Note To exit setting mode without saving settings, switch off operating voltage
for Multilube for a moment.
Settings, general
If the button is left in the setting mode, it returns to normal mode automatically after 3
minutes without saving new settings.