28
SKF Multilube-system troubleshooting
System troubleshooting
User interface does not operate
Operation disturbance Cause of operation
disturbance
Solution
Display and LED signals of
user interface are not lit.
No supply voltage on
pumping unit.
Check supply voltage.
User interface triggers an alarm
Operation disturbance Cause of operation
disturbance
Solution
The P LED-signal of user in-
terface is blinking
Lubricant reservoir is empty. Fill the lubricant reservoir.
Reset the alarm.
The LED-signal 1 or 2 for
line is blinking at the user
interface.
Header piping leaks.
There is air in the pumping
unit or in the header piping.
Wrong lubricant.
Locate and repair the
leakage.
Remove air from the
pumping unit or from the
header piping. Reset the
alarm.
See " choosing the
lubricant "